* When using a gas infrared burner,"Precautions for Use"Please read carefully before use.
Surface combustion is performed using gas only, allowing direct heating. It is also possible to burn in any direction. Infrared radiation can be easily achieved without the need for fans, blowers, heat exchangers, etc.
[Model number]
●DH-41A ●DH-61A ●DH-81A ●DH-101A ●DH-121A
●DH-42A ●DH-62A ●DH-82A ●DH-162A ●DH-42 ●DH-82
| Model |
Heat input (kw) |
gas consumption LP gas (kcal/h) |
gas consumption LP gas (kg/h) |
gas consumption City gas (㎥/h) |
weight (kg) |
Gas Connection Diameter | drawing |
| DH-41A | 1.57 | 1,350 | 0.11 | 0.12 | 3.0 | R6 | |
| DH-42 | 1.57 | 1,350 | 0.11 | 0.12 | 1.9 | R6 | |
| DH-61A | 2.36 | 2,030 | 0.17 |
0.18 |
3.9 | R6 | |
| DH-62 | 2.36 | 2,030 | 0.17 | 0.18 | 2.7 |
R6 |
― |
| DH-62A | 2.36 | 2,030 | 0.17 | 0.18 | 3.2 | R6 | |
| DH-81A | 3.14 | 2,700 | 0.22 | 0.24 | 5.5 | R10 | |
| DH-82 | 3.14 | 2,700 | 0.22 | 0.24 | 3.0 |
R10 |
|
| DH-82A | 3.14 | 2,700 | 0.22 | 0.24 | 4.5 |
R10 |
|
| DH-101A | 3.93 | 3,380 | 0.28 | 0.3 | 7.2 | R10 | |
| DH-121A | 4.72 | 4,060 | 0.34 | 0.37 | 9.0 | R10 | |
| DH-162A | 6.28 | 5,400 | 0.45 | 0.49 | 9.0 | R10 |
A special L-shaped plate is used to seal the gap between the wire mesh and the combustion plate, improving combustion efficiency. Compared to the standard type, the radiant energy is about 1.6 times higher. The combustion surface temperature increases by more than 100°C.
[Model number]
●DH-61AL ●DH-81AL ●DH-101AL ●DH-121AL ●DH-82L| Model |
Heat input (kw) |
gas consumption LP gas (kg/h) |
gas consumption City gas (㎥/h) |
weight (kg) |
Connection diameter |
| DH-61AL | 2.36 | 0.17 | 0.18 | 3.9 | R6 |
| DH-81AL | 3.14 | 0.22 | 0.24 | 5.5 | R10 |
| DH-101AL | 3.93 | 0.28 | 0.30 | 7.2 | R10 |
The burner body is equipped with an ignition rod/SN heater for quick and reliable automatic ignition of the burner.
*The heater can also be attached externally.
[Model number]
●DH-61AE ●DH-81AE ●DH-101AE ●DH-82AE
●DH-61AS ●DH-81AS ●DH-101AS ●DH-82AS
| Model |
Heat input (kw) |
gas consumption LP gas (kg/h) |
gas consumption City gas (㎥/h) |
weight (kg) |
Connection diameter |
| DH-61AE | 2.36 | 0.17 | 0.18 | 3.9 | R6 |
| DH-81AE | 3.14 | 0.22 | 0.24 | 5.5 | R10 |
| DH-101AE | 3.93 | 0.28 | 0.30 | 7.2 | R10 |
The burner body is made from stainless steel, which makes it more corrosion resistant than standard cast iron and also makes it lighter and simpler.
*Can only be used with forced exhaust installation equipment.
[Model number]
●SDN-61 ●SDN-81 ●SDN-101 ●SBM-801A
| Model |
Heat input (kw) |
gas consumption LP gas (kcal/h) |
gas consumption LP gas (kg/h) |
gas consumption City gas (㎥/h) |
weight (kg) |
Gas Connection Diameter | drawing |
| SDN-61 | 2.49 | 2,140 | 0.18 | 0.19 | 1.5 | R6 | |
| SDN-81 | 3.11 | 2,670 | 0.24 | 0.26 | 1.7 | R6 | |
| SDN-101 | 4.14 | 3,560 | 0.3 | 0.32 | 2.2 | R6 | |
| SBM-801A | 3.35 | 2,880 | 0.24 | 0.26 | 1.5 | RC8 |
FAQ
Product Features and Performance
Q.
A.
Q.
A.
Yes. It allows you to efficiently heat only the necessary areas.
Q.
A.
Surface combustion allows for combustion based on area rather than volume, enabling more efficient heat distribution and thus reducing gas consumption.
Specifications and Compatibility Requirements
Q.
A.
We support both LP gas and city gas.
Q.
A.
Our burners are consumables, so we request that you replace the burner unit periodically.
* While usage conditions may vary, we recommend a lifespan of 3 to 5 years for safe and efficient use.
Q.
A.
The burner is a consumable item and is subject to regular replacement. Therefore, disassembly, repair, or modification is not permitted.
Instructions for use and operation
Q.
A.
With the correct gas pressure supplied, it can be ignited quickly.
Q.
A.
Depending on the object being heated and the environment, the infrared radiation intensity is most effective at a distance of approximately 100 mm to 150 mm.
Q.
A.
Yes. It is designed for continuous operation.
Regarding how to handle problems and malfunctions
Q.
A.
The cause is thought to be a gas supply shortage, an ignition system malfunction, or a control device failure.
If the above issues are not present,we recommend replacing the burner unit.
Q.
A.
There is a possibility of damage to the ceramic plate or high gas pressure supply, so please shut off the gas supply immediately.
Q.
A.
The unit may not be burning properly and requires inspection or replacement. Please contact us for assistance.