FAQ
Q.
A.
The only manual tasks performed by the operator are scanning cylinder label, attaching the filling unit, and pressing the filling start button; all other operations are automated.
[MC-AD-Ⅲ filling operation procedure]
1. cylinder label | manual |
② Carrying cylinder into the filling machine | automatic |
③ Adjusting the height of the filling unit | automatic |
④ Installing the filling unit | manual |
⑤ Operate the filling start button | manual |
⑥ Open the cylinder valve | automatic |
⑦ Quantitative filling/excess/deficiency judgment | automatic |
cylinder Closing the container valve | automatic |
⑨ Removal of the filling unit | automatic |
⑩ Removal of cylinder after filling is complete | automatic |
Q.
A.
The MC-AD-III is equipped with cylinder transport conveyor in the weighing section of the filling machine, so cylinder are automatically loaded and unloaded.
Since the S-ER-A uses free rollers rather than a conveyor, cylinder are loaded and unloaded by hand.
MC-AD-III hasthe following cylinderreservation functions:

Q.
A.
If you scan the label of the next cylinder while filling, the next cylinder will be automatically brought in after automatic dispensing is completed.
Q.
A.
The valve closing operation is double-checked by a "torque check" and a "check of the closing end of the valve opening and closing cylinder." If either check is not completed, the filling unit is designed not to come off, so you can use it safely without worrying about gas leaks.
Q.
A.
cylinder from 50kg to 5kg (including siphons) can be filled semi-automatically. cylinder under 5kg can be filled with a manual nozzle.
Q.
A.
When the air pressure drops (below 0.4MPa), the filling valve closes automatically.
In addition, the valve is automatically closed to prevent gas leakage from the valve.